Accu Dyne Test
An information service of Diversified Enterprises
white bar
Overview Accu Dyne Test Contact Angle Measurement Tensionometry Searchable Bibliography

 

MATERIAL SAFETY DATA SHEET

Product Name: ACCU DYNE TEST™ MARKER PENS

Formula: HCONH2 + C2H5OC2H4 OH

Chemical Family: Amide/Glycol Ethers

I. INGREDIENTS:
Constituent
CAS No.
TLV
OSHA PEL
ethyl Cellosolve (C)*
110-80-5
5 ppm
29CFR
1910.1000
Formamide (F)
75-12-7
20 ppm
   
Methyl Violet 2B Dye
8004-87-3
n/a
   
Water (H)
n/a
n/a
   

*ethyl Cellosolve is a registered trademark of Union Carbide Corporation for 2-ethoxyethanol (ethylene glycol monoethyl ether).
Percentages by dyne level
Level
C (vol)
F (vol)
Level
C (vol)
F (vol)
30
100.0%
0.0%
48
13.0%
87.0%
32
89.5%
10.5%
50
9.3%
90.7%
34
73.5%
26.5%
52
6.3%
93.7%
36
57.5%
42.5%
54
3.5%
96.5%
38
46.0%
54.0%
56
1.0%
99.0%
40
36.5%
63.5%
42
28.5%
71.5%
Level
F (vol)
H (vol)
44
22.0%
78.0%
58
81.2%
18.8%
46
17.2%
82.8%
60
65.0%
35.0%

Dye concentrationvaries from 1.1 g/l at 60 dynes/cm to 2.0 g/l at 30 dynes/cm.

II. HAZARD SPECIFICATIONS: (under 29 CFR 1910.1000)

These hazards are associated with the fluids contained in ACCU DYNE TEST™ Marker Pens:
Reproductive Toxin Skin Hazard TLV = 20 to 200 ppm
Eye Hazard Kidney Toxin PEL = 5 ppm (8 hr weighted avg)
Sensitizer Toxic Agent EPA Hazardous Waste Class: n/a
Combustible Liquid Skin Irritant DOT Hazard Class: n/a

 

NFPA Hazard Signal: Health - 2; Stability - 0; Flammability - 0; Special - C

III. PHYSICAL DATA:
Boiling Point
(at 760 mm Hg)
135oC to 210oC Freezing Point,
(at 760 mm Hg)
-90oC to +2oC
Specific Gravity,
at 20oC (H2O = 1.0)
0.93 to 1.13 Vapor Pressure,
mm Hg, at 20oC
0.08 - 3.75
Vapor Density,
at 20oC (air = 1)
1.55 - 3.10 Solubility in Water,
% by wt. at 20oC
Complete
Percent Volatiles
(by volume)
100% Evaporation Rate
(Butyl Acetate = 1)
<0.1 to 0.32
Appearance and odor: Dark violet solution with mild, non-residual odor.

 

IV. FIRE AND EXPLOSION DATA:

Flash Point: 108oF to 245oF, per ASTM D56; tag closed cup.

Autoignition Temperature: n/a

Flammability Limits in Air (by vol. at 200oF): 1.7% to 15.6%

Extinguishing Media: Water fog recommended; CO2, dry chemical, and universal foam media, as applied by manufacturer's recommendations, can also be used.

Unusual Fire/Explosion Hazards: Can react with oxidizing materials.

V. HEALTH HAZARD DATA:

Inhalation: Vapors are irritating to eyes, nose, and respiratory tract. May cause headache, nausea, vomiting, weakness.

Skin Contact: May cause irritation. Wear protective gloves.

Ingestion: See inhalation; can also cause breathing difficulty. Kidney damage may result from ingestion of large quantities of test solution.

Skin absorption: Prolonged or widespread contact with skin may lead to absorption of harmful amounts of material resulting in symptoms as described under ingestion.

Eye Contact: Causes marked irritation.

SPECIAL WARNING: Pregnant women should not use this product; laboratory studies of animal subjects have shown birth defects, delayed fetal development, and increased fetal mortality at air concentrations of 150 to 200 ppm.

VI. EMERGENCY AND FIRST AID PROCEDURES:

Eyes Flush liberally with running water. Call a physician.

Skin Immediately remove contaminated clothing. Thoroughly wash affected area with soap and water.

Inhalation Remove to fresh air. If breathing is difficult, give oxygen and call a physician.

Ingestion Give large quantities of water. Induce vomiting. Call a physician.

VII. REACTIVITY DATA:

Decomposes partially at temperatures above 180oC. Do not combine with concentrated alkali at elevated temperatures.

Hazardous combustion or decomposition products: CO, NHx.

VIII. SPILL OR LEAK PROCEDURES:

Absorb spill with paper toweling or vermiculite. Once absorbed, evaporate outdoors or incinerate in a chemical burner equipped with an after-burner and scrubber.

Dispose of waste product by high temperature incineration, as approved under appropriate federal, state, and local legislation. Do not discharge without prior written approval from the appropriate health and environmental authorities.

IX. SPECIAL PRECAUTIONS

NOT FOR USE AS A CONSUMER PRODUCT. FOR INDUSTRIAL USE ONLY.

Keep this product away from heat and flame. Always use with adequate ventilation. Do not allow fluid to contact skin; wear gloves.

WARNING TO PREGNANT WOMEN: Do not use ACCU DYNE TEST™ marker pens unless exposure is extremely low. Even small amounts, if repeatedly inhaled, ingested, or absorbed through skin, may cause fetal malformations.

 

While Diversified Enterprises believes the information contained herein is factual and the opinions expressed are those of qualified experts, this information is not to be taken as a warranty for which Diversified Enterprises assumes legal responsibility. It is provided solely for consideration, investigation, and verification.

Russell E. Smith, President
December 3, 2008

PDF Icon Download PDF version of this document.

previous page | top of page

Diversified Enterprises
101 Mulberry St., Suite 2N
Claremont, NH 03743 U.S.A.
(603) 543-0038 or 1-800-833-4644; fax (603) 543-1334
Emergency telephone: 1-800-424-9300 (Chemtrec)
E-mail us
©2003-2008 Diversified Enterprises

site by
webkewl